All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
0
Views
0
Downloads

Authors

Background: A 62-year-old man with suspected lymphoproliferative disease awaiting gastroscopy to confirm the localization of hematologic pathology in the stomach underwent first-level coagulation according to prehospitalization protocols. As the PT was prolonged and the aPTT was indeterminable. The blood coagulation profile tests revealed a few important changes: the PT was 5.03 (i.e. 0.80- 1.15) and the aPTT ratio (i.e. 0.85- 1:20) was indeterminable.

Case Report: The aPTT was then performed with the patient’s normal plasma pool plasma mixture at a ratio of 1:1, achieving a ratio of 6.04. The determination of lupus anticoagulant performed with dRVVT was positive. Antiphospholipid antibody (aPL) determination showed a positive value for anticardiolipin antibody IgM (6126 U7m/L; v.r. <20). In contrast, the anti-inflammatory antibodies β2-glycoprotein-I (aβ2GPI) IgG and IgM were both negative. The specific factors (II, V, VII, IX, IX and XI) were normal. Serum electrophoresis indicated the presence of a migrating monoclonal component (CM) in the γ-globulin zone. In the subsequent immunofixation of the serum, the CM could be typed in IgM-kappa (17.8 g/L). It was therefore hypothesised that the abnormal protein component could interfere with the coagulation tests. To test this hypothesis, the following experiment was planned: Isolation of CM IgM-kappa by polyacrylamide gel electrophoresis in the presence of sodium dodecyl sulphate and subsequent purification using HiTrap IgM Purification HP columns. The resulting CM was added in progressively increasing concentrations to a pool of normal plasma (PNP); PT and aPTT were performed with these different concentrations.

Results and Conclusions: The results showed a prolongation of both tests, a phenomenon that was not observed when a buffer solution was added to the PNP. Finally, these clotting times were checked with thromboelastography, which gave normal results. In this way, it was possible to determine the extent to which CM is functionally able to interfere with the system for determining clotting time.